CO₂ Incubators

CO₂ Incubators


Specially designed to protect valuable samples with superior contamination control. It is built to accommodate even the most demanding cell cultures and lab requirement or optimal cell culturing.


Types to choose from:

• Heating method: water- or air-jacketed.

• Decontamination: UV lamp; 90°C or 180°C  heat sterilisation.

• Inner door: 1, 3 or 6.


Ordering Information


Model

RLCO290

RLCO2240

RLCO2151UV

RLCO2212UV

RLC02180

RLC02160W

Construction

 Exterior Dimensions

 (WxDxH)

637 x 762 x 909 (mm)

25.1 x 30.0 x 35.8 (inch)

780 x 820 x 944 (mm)

30.7 x 32.3 x 37.2 (inch)

615 x 768 x 865 (mm)

24.2 x 30.2 x 34.1 (inch)

910 x 763 x 795 (mm)

35.8 x 30.0 x 34.1 (inch)

655 x 656 x 1030 (mm)

25.8 x 25.8 x 40.5 (inch)

655 x 656 x 1030 (mm)

25.8 x 25.8 x 40.5 (inch)

 Interior Dimensions

 (WxDxH)

470 x 530 x 607 (mm)

18.5 x 20.8 x 23.9 (inch)

607 x 583 x 670 (mm)

23.9 x 22.9 x 26.4 (inch)

470 x 530 x 607 (mm)

18.5 x 20.9 x 23.9 (inch)

600 x 588 x 600 (mm)

23.6 x 23.1 x 23.6 (inch)

544 x 504 x 681 (mm)

21.4 x 19.8 x 26.8 (inch)

544 x 504 x 681 (mm)

21.4 x 19.8 x 26.8 (inch)

 Interior Volume

151L/5.3cu.ft.

240L/8.5cu.ft.

151L/5.3cu.ft.

212L/7.5cu.ft.

185L/6.5cu.ft.

185L/6.5cu.ft.

 Net Weight

80kg/176Ibs.

80kg/176Ibs.

75kg/165Ibs.

95kg/209Ibs

43.5L/1.54cu.ft

43.5L/1.54cu.ft

 Interior

Type 304, mirror finish, stainless steel

 Exterior

Electrolyzed galvanization steel, powder coated

Cold-rolled steel,

power coated

 Inner door

3 inner doors standard

6 mini inner doors optional one inner door standard

one inner door standard

one inner door standard

one inner door standard

 Temperature

 Heating Method

Direct Heat & Air Jacket (DHA)

Water Jacket

 Temp. Control 

 System

Microprocessor

Microprocessor

Microprocessor

Microprocessor

Microprocessor

Microprocessor

 Temp. Sensor

PT1000

PT1000

PT1000

PT1000

PT1000

PT1000

 Temp. Range


5°C above ambient temperature to 50°C

Ambient +2 to 55

5°C above ambient temperature to 55°C

 Temp. Uniformity

±0.2°C

±0.2°C

±0.2°C

±0.3°C

±0.2°C

±0.2°C

 Temp. Stability

±0.1°C

±0.1°C

±0.1°C

±0.1°C

±0.1°C

±0.1°C

 CO2


 Inlet Pressure

0.1 Mpa

0.1 Mpa

0.1 Mpa

0.1 Mpa

0.1

0.1 Mpa

 CO2  Control System

Microprocessor

Microprocessor

Microprocessor

Microprocessor

Microprocessor

Microprocessor

 CO2  Sensor

Thermal conductivity

Thermal conductivity

Thermal conductivity

Thermal conductivity

Thermal conductivity/

Infrared

Thermal conductivity/ 

Infrared

 CO2  Range

0 to 20%

0 to 20%

0 to 20%

0 to 20%

0 to 20%

0 to 20%

 CO2  Stability

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

 Humidity

 Humidifying System

Special designed water reservoir

Humidity pan

 Relative Humidity

≥95%

≥95%

≥95%

≥95%

≥95%

≥95%

 Water Reservoir

 Volume

3L

3L

4L

6L

3

3L


Model

RLCO290

RLCO2240

RLCO2151UV

RLCO2212UV

RLC02180

RLC02160W

Shelves

Shelf dimensions (WxD)

423 x 445 (mm)

16.7 x 17.5 (inch)

423 x 445(mm),

16.7 x 17.5(inch)

423x445 (mm)

16.7 x 17.5 (inch)

590x510(mm)

23.2x20.1 (inch)

453 x 433

466 x 440 (mm)

18.3 x 17.3 (inch)

Shelf construction

3, 10

3, 12

3, 10

3, 12

3, 10

3, 11

Standard, Maximum

Type 304, mirror finish, stainless steel

Type 304, mirror finish, 

stainless steel, perforated, 

adjustable

Type 304, mirror finish,

 stainless steel

Max. Load per Shelf





10kg (22.05 lbs)


Fittings

Access port

Standard

Standard

Optional

Optional

Standard

Standard

Air filter

0.3µm, Efficiency: 99.998% (for CO2)


Remote alarm contacts

Standard

Standard

Standard

Standard

Standard

Standard

Decontamination


90°C moist heat 

disnfection

90°C moist heat 

disnfection

UV lamp

UV lamp

180°C dry heat 

disinfection  on all 

internal surfaces

HEPA filter system

Rated Power


600W

735W

600W

700W


430W

Power Supply


220V/50Hz (standard), 

110V/60Hz (Optional)

220V/50Hz (standard), 

110V/60Hz (Optional)

220V/50Hz (standard), 

110V/60Hz (Optional)

220V/50Hz (standard), 

110V/60Hz (Optional)

220V/50Hz (standard), 

110V/60Hz (optional)

220V/50Hz (standard), 

110V/60Hz (optional)

Alarm System


Power interruption* High/low temperature* Deviation of CO2* RH* Door ajar* Independent overheat protection


Power interruption*

High/low temperature* 

Deviation of CO₂*

RH* 

Door ajar*

Independent overheat

protection

Power interruption*

High/low temperature* 

Deviation of CO₂*

RH* 

Door ajar*

Independent overheat

protection


Data Output


RS232

RS232

-

-

RS232, Remote Alarm 

Contacts, USB

RS232


Related Products
×
添加微信好友,了解更多产品

点击复制微信号

微信号:

复制成功
微信号:
添加微信好友,了解更多产品
去微信添加好友吧

Tel

(+65) 8487 7719
7*24

TOP